Ovizio iLine F PRO Analyzer

Live Cell Analyzer

  • Real-time & automated process analytical technology
  • Label-free cell analysis
  • Closed-loop system
  • Maximized availability of biological sample
  • 21 CFR Part 11/GMP-ready software

The Ovizio iLine F PRO is an online microscope for continuous monitoring of critical quality attributes in bioprocesses. It is engineered to work with wave bags, single-use and stirred tank bioreactors and has been designed for cGMP compliance.

The platform features the iLINE-F, a holographic microscope, and the BioConnect, a disposable that connects to the culture vessel with a built-in pump system. Cells are continuously drawn into the microscope, analyzed, and returned intact to the culture. Machine learning algorithms enable cell detection and continuous tracking of multiple parameters such as viability, bead count, cell activation profile, and cell infection status.

With the OsOne software, you get easy data access as well as online acquisition information and quantitative data analysis of your suspension cell cultures. The intuitive interface and wizard enable a rapid understanding and navigation through the app. Improved user traceability is integrated to ensure compliance with 21 CFR Part 11 guidelines.

Optimize your bioprocess efficiency through real-time cell monitoring.

 

If you would like to receive the iLine F PRO User Manual or Technical Support Manual please contact us here

Type iLine F holographic transmission microscope
Light source Partially coherent monochromatic LED 630 nm (red)
Sensor C-MOS camera 2456 (H) x 2058 (V) – 8 bits
Analyzer objective Olympus LUCPLFLN20X analyzer objective 20x – 0.45 NA
Total magnification Olympus LUCPLFLN20X analyzer objective 20x – 0.45 NA
Horizontal resolution 1.5 µm
Field of view 318 µm x 318 µm
Acquisition rate 15 fps max
Data volume 128 Mb per measurement point. Note: volume may vary depending on selected cell line
Integration capabilities  
Device 400 (15.7’’ – L) x 223 (9.2” – W) x 423 (16.7” – H) mm – 21 kg
Shipment box 515 x 320 x 550 mm
OsOne specifications
 
  OPC ready, automation via RESTful web services
GMP mode Compliant with 21 CFR part 11
Data output object count, viability, viable cell density, total cell density

 

 

BioConnect  
Cell concentration range Cell counting range of 0.5 to 10 Mcells/mL The device provides a ± 10% cell density variationVia1-Cassette™
Typical flow rate From 4 to 12 mL/min
Cell travel time 5 to 25 min. Varies according to specific setup (pump profile, total …)
Tubing length 180 cm of silicon 1 x 3 mm + 2 * 40 cm of PVC 3.1 x 4.2 mm
Welding interface PVC tubing (3.1 x 4.2 mm ID x OD)
Adressable bioreactor volume From 300 mL to 10.0 L total process
Retention volume 4.8 mLto8.3 mL Note: Retention volume of BioConnect only, other tubing added between vessel and BioConnect will increase these values
Sterilization Gamma irradiation (25 kGy) and individual packaging
Flow cell channel height Between 150 and 200 µm
Hygrometry 20-80% -non-condensing
Temperature 15-25 °C
Shelf life 6 months at storage temperature from 15 to 30°C
Bioreactor inner pressure limitation Max 7.25 [500] psig [mbarg]
Regulatory compliance All fluid-contact materials have passed current USP Biological Test or ISO 10993 certification
Symbols glossary
SYMBOL STANDARD REFERENCE SYMBOL TITLE EXPLANATORY TEXT
ISO 15223- 1:2016
Reference no. 5.1.1.
(ISO 7000-3082)
Manufacturer  Indicates the product manufacturer.
ISO 15223- 1:2016
Reference no. 5.1.3.
(ISO 7000-2497)
Date of manufacture Indicates the date when the product was manufactured.
ISO 15223- 1:2016
Reference no. 5.1.4.
(ISO 7000-2607)
Use by date Indicates the date after which the product is not to be used.
ISO 15223- 1:2016
Reference no. 5.1.5.
(ISO 7000-2492)
Batch code Indicates the manufacturer’s batch code so that the batch or lot can be identified.
ISO 15223- 1:2016
Reference no. 5.1.6.
(ISO 7000-2493)
Catalogue number Indicates the manufacturer’s catalog number so that the product can be identified.
ISO 15223- 1:2016
Reference no. 5.1.7.
(ISO 7000-2498)
Serial number Indicates the manufacturer’s serial number so that a specific product can be identified.
ISO 15223-1:2016
Reference no. 5.2.4.
(ISO 7000-2502)
Sterilized using irradiation Device is provided sterile and has been sterilized using irradiation.
ISO 15223-1:2016
Reference no. 5.2.6.
(ISO 7000- 2608)
Do not resterilize Indicates a product that is not to be resterilized.
ISO 15223- 1:2016
Reference no. 5.3.2.
(ISO 7000-0624)
Keep away from sunlight Indicates a product that needs protection from light sources.
ISO 15223- 1:2016 and
ISO 15223-1:2020(E) DRAFT
Reference no. 5.3.4.
(ISO 7000-0626)
Keep away from rain Indicates a product that needs protection from moisture.
ISO 15223- 1:2016
Reference no. 5.3.7.
(ISO 7000-0632)
Temperature limit Indicates the temperature limits to which the product can be safely exposed.
ISO 15223- 1:2016
Reference no. 5.2.8.
(ISO 7000-2606)
Do not use if package is damaged Device is not be used if the package is damaged or opened.
ISO 15223-1:2016E
Reference no. 5.4.2.
(ISO 7000- 1051)
Do not re-use

Indicates a product that is for single use only and must not be used more than once.

NOTE: Synonyms for “Do not reuse” are “single use” and “use only once”.

ISO 15223-1:2016
and ISO 15223-1:2020
Reference no. 5.4.3.
(ISO 7000-1641)
Operator’s manual; operating instructions Indicates the need for the user to consult the user manual before use.
ISO 15223- 1:2016
Reference no. 5.4.4.
(ISO 7000-0434A)
Caution To indicate that caution is necessary when operating the device.
Directive 2012/19/EU WEEE; waste electrical and electronic equipment; crossed-out wheeled bin Separate collection for waste electric and electronic equipment (WEEE) is required.
IEC 60417 – 5031 Direct current Indicates on the rating plate that the equipment is suitable for direct current only.

 

This web page is provided in compliance with the virtual patent marking provisions of the America Invents Act. The Ovizio products listed below are protected by the listed patents in the United States. These Ovizio products may be protected by additional patents, and other patents may be pending, in the U.S. or other jurisdictions. This list is updated approximately twice per year and was last updated: July 31, 2024.

Product U.S. Patents
iLine F PRO 11,067,379
10,025,271
9,684,281
12,055,540
9,207,638
9,476,694
qMod 10,025,271
9,684,281
12,055,540
9,207,638
9,476,694
BioConnect 11,067,379
AVIO 10,578,541
10,025,271
9,684,281
12,055,540
9,207,638
9,476,694